Terms and Definitions

R-SOT-02

SOT Removal MT-100

MT-100 MiniTweez
MT-100 MiniTweez
SOT's
SOT's

1. Remove conformal coating (if any) and clean work of any contamination, oxides or residues.

2. Set a tip temperature of 343°C (650°F) for lead-free or 316°C (600°F) for leaded alloys and adjust as necessary.

3. Install and align SOT Removal Tips into the MiniTweez® using Tip Tool.

4. Apply flux to all lead/land areas. (A)

5. Clean residue from tips with damp Sponge Tool from Tip Maintenance Station. (B)

6. Lower tips over component and Gently tweeze handpiece contacting ALL leads with tips. (C)

7. Confirm solder melt of ALL joints and lift component from PCB. (D) & (E)

8. Release component from tips by wiping on a heat resistant surface.

9. Return the MiniTweez® to its Tip & Tool Stand.

10. Prepare lands for component replacement.

PACE Intelliheat® Power Supply 

MT-100 MiniTweez® 

SOT Removal Tips (See Chart on Back) 

Tip Tool 

Tip Maintenance Station 

Flux-cored Solder 

Cleaner 

Product Image Dimensions Part Number
1124-1001-P1
1124-1002-P1
1124-1003-P1
1124-1004-P1
1124-1011-P1